亚洲人亚洲人成电影网站色-日韩人妻无码一本二本三本-18禁黄无码免费网站高潮-久久精品国产99国产精品导航-小12箩利洗澡无码视频网站

Welcome to the official website of Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.!
Position首頁 > Home > Industrial Safety Products > Safety Controller > Programmable safety controller
SM 302 safety relay

     

     As the most important part of safety loop, safety controller/safety PLC has been recognized by more and more people, but in the process of use, there are still many users who are confused about the differences between safety relay and ordinary relay, so I would like to share them with you here. As we all know, we must remember three words in the concept of safety design:

(1) Redundancy

(2) Difference

(3) Self-detection

        How to construct the safety loop with the reliability above PLd, the safety controller must become an important link. The safety loop consists of safety input, safety control and safety output subsystems, and the safety control "including safety relay, safety controller, safety PLC, etc." realizes the safety control function. Designers match different safety controllers to achieve the reliability level of the safety loop according to the number of products at the input end.


▊ SM-302 programmable safety controller
1666939573713918.png

· Is a configurable safety controller, which supports the input of various safety product components.

·Maximum support for 3 sets of dual-loop inputs.

·Iso 13849-1 performance index PLe

·Built-in self-diagnosis function for fault detection

·Modbus protocol communication

·Input and output fault indicator light

·Safety certification: PL e, Cat: 4


Product selection

product name

model

Safety input

Safe output

brand

Programmable safety controller

SM-302

3CH

2NO

LHS
explain

Up to 3 sets of dual-channel security products can be entered.

The programming software defines the field safety products by itself.

Official website programming software download connection.:http://lhsafety.com.cn/showinfo-257-118-0.html


safety performance

·Performance level (PL): PLE

·Safety category (cat.): cat.4.

·Task time (TM): 20 years.

·Diagnostic coverage (DC/DC AVG): 99%

·Safety integrity level (SIL): SIL3

·Hardware fault margin (HFT): 1

·Safety Failure Score (SFF): 99%

·PFHD: 1.78e-9/h

·Stop category: 0/1               

Comply with the standard EN ISO13849

Comply with the standard EN ISO13849

Comply with the standard EN ISO13849

Comply with the standard EN ISO13849

Comply with standards IEC61508, IEC62061.

Comply with standards IEC61508, IEC62061.

Comply with standards IEC61508, IEC62061.

Comply with standards IEC61508, IEC62061.

Comply with standard EN 60204-1.


Main technical parameters

Power supply characteristics

·Power supply voltage: 24VDC

·Voltage range: 20~30VDC

·Current loss: ≤100mA(24VDC)

Input characteristics

·Input current: ≤10mA(24VDC)

·Conductor resistance: ≤15Ω

·Input equipment: emergency stop button, safety door, two-hand button,

·Safety light curtain, magnetic switch, etc

·Input channel: 3

output characteristic

·Number of contacts: 2NO (safety output)

·Contact material: AgSnO2

·Contact fuse protection: 10A is fast, 6A is slow.

·Switching capacity: 5A/230VAC;; 5A/24VDC

Time characteristic

·Suction buffer time:≤100ms

·Release buffer time:≤30ms

·Recovery time:

         Emergency stop operation:≤30ms

         Power failure:≤1000ms

·Recovery time:

         Emergency stop operation:≤30ms

         Power failure:≤100ms

·Short-term interruption of power supply:20ms

Communication characteristics

·Baud rate: 38.4kbps (fixed)

·Communication length: ≤1000m

·Networking capacity: ≤10 units


Environmental characteristic parameters

·Electromagnetic compatibility: comply with EN60947, EN61000-6-2 and EN61000-6-4.

·Vibration frequency: 10Hz~55Hz

·Vibration amplitude: 0.35mm

·Operating temperature: -20℃~+60℃

·Storage temperature: -40℃~+85℃

·Relative humidity: 10%~90%

·Overvoltage grade: Ⅲ

·Pollution level: 2

·Altitude: ≤2000m

·Rated isolation voltage: 250VAC.

·Rated impulse voltage: 6000V(1.2/50us)

·Insulation strength: 1500VAC for 1min.

·Electrical clearance and creepage distance: in accordance with EN60947-1.

302 22.10.27處理過原圖加了影印.png


Functional application parameters

functional block diagram

Typical application

圖片3.png

圖片4.png


Input element: CH1 (emergency stop button); CH2 (emergency stop button); CH3 (reset button)

Control Logic: CH1&CH2

Reset mode: manual reset.

Output delay: 0s

Safety level: Cat.4 performance level: PLe safety integrity level: SIL 3


Wiring diagram

Power Supply 

1.png

correspondence

1655948458157829.png

input

1655948540921377.png1655948633175148.png1655948716671157.png
6.png7.png
9.png10.png

reset

11.png12.png

feedback

13.png14.png

output

15.png

     


Related Products
Download
PDF file download
Video file download
Previous

Contact us

400-881-6062

Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

E-Mail: info@lh-safety.com

Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

(Greenland East Coast International Plaza-Room A 313)

Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

Online service

Online message

  • Click to refresh
  • 主站蜘蛛池模板: 国产av亚洲精品ai换脸电影| 日日摸夜夜爽无码毛片精选| 99久久国产露脸国语对白| av色综合久久天堂av色综合在| 色舞月亚洲综合一区二区| 精品一区二区三区无码视频| 久久大香萑太香蕉av| 黑人巨大精品欧美| 国产精品久久久久久爽爽爽| 国产人成视频在线视频| 国产人妻人伦精品1国产丝袜| 国产成人小视频| 成 人 a v免费视频在线观看 | 午夜福利1000集在线观看| 久久综合乱子伦精品免费| 91精品少妇一区二区三区蜜桃臀| 欧美乱码精品一区二区三区| 精品国产av 无码一区二区三区| 猫咪av成人永久网站在线观看| 国产精品福利视频萌白酱| 老牛精品亚洲成av人片| 亚洲中文字幕日产乱码在线| 中文毛片无遮挡高潮免费| 亚洲午夜理论无码电影| 精品综合久久久久久97| 歪歪爽蜜臀av久久精品人人| 露脸内射熟女--69xx| 亚洲国产欧美在线成人app| 国产高清av久久久久久久| 爽爽精品dvd蜜桃成熟时电影院| 无码人妻毛片丰满熟妇区毛片国产 | 免费99精品国产自在在线| 黄色视频网站免费| 亚洲色欧美色2019在线| 高清国产天干天干天干不卡顿| 久久婷婷五月综合97色直播| 国产色系视频在线观看| 自偷自拍亚洲综合精品第一页| 少妇被躁爽到高潮无码文| av无码不卡在线观看免费| 成人性能视频在线|